6. Other
6.3.19

Fusing Motor (M7)

[5]
6.3.20

Developing Motor (M3)

[1]
54
[1]
[3]
[2]
[4]
4139fs2043c1
[2]
4139fs2044c1
4139fs2068c2
Field Service Ver. 4.0 Feb. 2006
1. Remove the Right Cover.
☞ 34
2. Remove two screws [1] and the con-
nector [2].
3. Remove the harness [3] from the wir-
ing saddle [4] and then remove the
Fusing Motor [5].
1. Remove the Front Cover.
☞ 34
2. Remove the screw [1] and the Safety
Switch Assy [2].
Precautions for Reinstallation of the
Safety Switch Assy
• Check that the switch is actuated
with the Front Cover and the Upper
Cover closed.
• Make sure that the distance
between the switch lever and
switch case (with the switch in the
actuated position) falls within the
specified range.
Specifications: 0.1 to 1.0 mm