Abus Terxon MX Installation Instructions Manual page 83

Intruder alarm panel terxon mx
Table of Contents

Advertisement

2. The LCD display shows: 185:KsAutoRstOFF
3. Via the keypad, select from the following items
and press:
KsAutoRstOFF
0
The user must manually reset any
triggered zones.
KsAutoRstON
The system automatically resets zone
1
types KM or KF when the user activates
using the key switch.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
186 Number of home „beep" calls
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 186:HB calls 02
3. Via the keypad, select from the following items
and press:
HB calls 01-15
01-15
Number of calls with report type
home „beep" (command 103=6)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
191 Fast format channel 1
To change the settings::
1. On the control unit, enter:
2. The LCD display shows: 191:Fire
3. Via the keypad, select from the following items
and press:
186
191
83
Not Used
00
01
Fire
PA
02
03
Burglar
04
Open/Close
05
Alarm Abort
06
Technical Alarm
Alarm Confirmation
07
08
RF Low Battery
RF Supervision Loss
09
10
RF Jamming
11
AC Fail
12
Tamper Alarm
13
Open
Close
14
15
Zone Omitted
Medical
16
17
Keybox
18
AntiMask
19
Smoke Detector
20
Comms Acknowledge
21
Battery Fault
22
System Alarm
In a partitioned system
23
Alarm partition A
24
Alarm partition B
Alarm partition C
25
26
Alarm partition D
30
Pulse Set 1
31
Pulse Set 2
32
Pulse Set 3
33
Pulse Set 4
34
Unset 1
Unset 2
35
36
Unset 3
37
Unset 4
UK

Advertisement

Table of Contents
loading