Abus Terxon MX Installation Instructions Manual page 88

Intruder alarm panel terxon mx
Table of Contents

Advertisement

Fire Z -- Rstr
Soak Fail Z --
Bell Tamper
Rst
Bell Tamper
UK
System
Rearmed
System
Startup
Tamper Z --
Tamper Z --
Restore
Tech Z --
Alarm
Tech Z --
Restore
Tel Line Fault Error in transmission (not for Terxon S)
Tel Line
Restrore
User--
Change User-
-
User-- Delete
User--
U -- Off-Site
U -- On-Site
User--
System Reset
User-- # Set
User-- #
Unset
User--
Time/Date
User Zone #
Omit
User Zone #
Unomit
Global
Tamper
Global T.
Restore
Zone nn fire alarm reset
Zone nn sensor test failed
Siren tamper alarm reset
Siren tamper alarm triggered
System automatically rearmed
System supplied with power and started
Zone nn has triggered a panic alarm
Zone nn panic alarm reset
Zone nn has triggered a technical alarm
Zone nn alarm reset
Transmission error reset
User nn has changed the user code of
user nn
User nn has deleted the user code of
user nn
User nn has exited the program menu
User nn has entered the program menu
User nn has reset the alarm centre
User nn has activated the alarm centre
(area #)
User nn has deactivated the alarm
centre (area #)
User nn has changed the time and date
User nn has removed ZN nn from
monitoring
User nn has returned ZN nn to
monitoring
Only for zone property NC + tamper:
Tamper line (COM A/T) triggered
Tamper line (COM A/T) reset
091 Test output 1
The alarm centre activates output 1 on the centre's PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:
1. On the control unit, enter:
2. To end the test, press:
092 Test output 2
The alarm centre activates output 2 on the centre's PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:
1. On the control unit, enter:
2. To end the test, press:
093 Test output 3
The alarm centre activates output 3 on the centre's PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:
1. On the control unit, enter:
2. To end the test, press:
094 Test loudspeaker output
The alarm centre activates the output for the optional
loudspeaker on the PCB until it is terminated manually. To
start the test, you must open the program menu. Proceed
as follows:
1. On the control unit, enter:
2. To end the test, press:
095 Test control unit buzzer
The alarm centre activates the control unit buzzer until it is
terminated manually. To start the test, you must open the
program menu. Proceed as follows:
1. On the control unit, enter:
2. To end the test, press: