Abus Terxon MX Installation Instructions Manual page 78

Intruder alarm panel terxon mx
Table of Contents

Advertisement

143 Contact ID report Rst
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 143:Mode=Bas+Res
UK
3. Via the keypad, select from the following items
and press:
0
1
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
151 Additional outputs
By using the cable supplied or the optional relay PCB, you
have access to eight further transistor outputs. To change
the setting of output 1:
1. On the control unit, enter:
2. The LCD display shows: 151:Fire
3. Via the keypad, select from the following items
and press:
00
01
02
03
04
05
06
07
143
Mode=Basic
All reports with numbers as in the „CID
Code" column apart from those marked
with a # (see appendix, SIA Report
Mode)
Mode=Bas+Res
All reports with numbers as in the „CID
Code" column (see appendix, SIA
Report Mode)
151
Not Used
Fire
PA
Burglar
Open / Closed
Alarm Abort
Technical Alarm
Alarm Confirmation
RF Low Battery
08
09
RF Supervision Loss
RF Jamming
10
11
AC Fail
12
Tamper Alarm
13
Open
14
Close
Zone Omitted
15
16
Medical
Keybox
17
18
Anti-Mask
19
Smoke Detector
20
Comms Acknowledge
21
Battery Fault
System Alarm
22
23
Alarm partition A
Alarm partition B
24
25
Alarm partition C
26
Alarm partition D
30
Set 1
31
Set 2
32
Set 3
33
Set 4
Unset 1
34
35
Unset 2
36
Unset 3
37
Unset 4
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
152 Additional outputs
Additional output 2
78