030 Panic silent
To change the property of the silent panic alarm:
1. On the control unit, enter:
2. The LCD display shows: 030:PA audible
3. Via the keypad, select from the following items
and press:
PA audible
0
When a panic alarm is triggered, the
alarm centre generates a local alarm.
PA silent
When a panic alarm is triggered, the
1
alarm centre generates no local alarm.
The alarm is issued only via the relay
contacts and via the optional dialler.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
031 Zone tamper
Proceed as follows to change the property of zone
tampering:
1. On the control unit, enter:
2. The LCD display shows: 031:EngTmpRstOFF
3. Via the keypad, select from the following items
and press:
EngTmpRstOFF
No program code necessary (OFF).
0
If a tamper alarm is triggered, you only
have to enter the user code to
acknowledge the tamper message.
EngTmpRstON
Program code required (ON)
If a tamper alarm is triggered, you have
1
to enter the user code to deactivate the
alarm and then the program code to
delete the tamper alarm.
4. Confirm your input. On the control unit, enter:
.
030
031
51
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
032 Control units and partitions
If you have created a partitioned system then using this
function, you can assign entry/exit zones, alarm zones
and status displays of partitions to the control units. To
change this feature, proceed as follows:
1. On the control unit, enter:
2. The LCD display shows: 032: Keypd 1 abcd
3. Via the keypad, select from the following items
and press:
Assignment of control unit 1 to partition
A
A
Assignment of control unit 1 to partition
B
B
Assignment of control unit 1 to partition
C
C
Assignment of control unit 1 to partition
D
D
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
Repeat these steps for the remaining control units.
(1. Basic setting: all control units belong to all partitions. 2.
Key switches connected to control units can not be
individually assigned to partitions. 3. Panic alarms apply to
all partitions.
033 System Reset
To change the property of the system reset:
1. On the control unit, enter:
2. The LCD display shows: 033: EngReset OFF
3. Via the keypad, select from the following items
and press:
EngReset OFF
0
If a system error is displayed, you only
have to enter the user code to