1
Connection of 230V mains supply with primary fuse (T 250V 250mA).
2
230V AC / 12V DC transformer
3
Connector strip for siren, flashlight, programmable outputs, loudspeakers, 12VDC power supply and
alarm zones.
4
Connection of tamper contacts of the housing of the alarm centre.
5
Terminal connector strip for standby battery.
6
Terminal connector strip for control units.
7
Terminal connector strip for extra transistor outputs or the optional relay module.
8
Room for 12V standby battery (7Ah) and cabling.
9
Connection for PC data cable
Connections for telephone line
Note for 230 V connection
Do not switch on the mains power yet!
Connect the mains power to the terminal connector strip as follows:
neutral (blue)
ground (green/yellow)
Phase (black)