Simrad AP50 Installation Manual page 37

Autopilot standard system
Hide thumbs Also See for AP50:
Table of Contents

Advertisement

Simrad AP50 Autopilot
Note !
Note !
28
See Table 2-5 for pin configuration and color code of the
network cable. DO NOT MIX THE PINS AND THE CABLE
COLORS!
Apply a thin layer of pure Vaseline (petroleum jelly) on the
connector threads and make sure the connectors are properly
secured to the receptacle by the coupling ring. When properly
installed, the connectors are weatherproof according to IP56.
All unused Robnet plugs must be fitted with plastic caps to keep
the connectors free of dirt and moisture. A separate screw cap
for the control unit is included in the installation kit.
6
1
5
2
4
3
FRONT VIEW
Table 2-5 Robnet Plug Pin Configuration
AP50
CONTROL
UNIT
Figure 2-23 Control Unit Connection
For installations that require special cable lengths, contact your
Simrad distributor for information.
Cable
Color
pairs
code
st
1
pair
Pink
Grey
nd
2
pair
Brown
White
rd
3
pair
Yellow
Green
JUNCTION UNIT
MAIN PCB
Pin
Signal
5
V SYSTEM+
4
V SYSTEM–
1
Bus–
2
Bus+
3
On - Off
6
ALARM
Bn
Gn
Wh
Pnk Gry Yel
ROBNET
20222469 / B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents