Inverter/Charger Installation

Auxiliary (AUX) Port

AUX+12V Voltage Supply

2–26
The auxiliary output is designed to provide the following functions:
Auxiliary 12 VDC power supply
Remote power off
The auxiliary port provides 12 VDC/250 mA output to control a relay, fan,
indicator light, or other device. The auxiliary output can be configured (using a
Xantrex XW System Control Panel) to trigger in response to:
low battery voltage
high battery voltage
low battery temperature
high battery temperature
any device fault
The auxiliary output can also be triggered manually using the Xantrex XW System
Control Panel.
The 12 VDC output can trigger a relay to disconnect batteries from the inverter/
charger when battery voltage or temperature are out of the ideal range.
Figure 2-16 AUX Port Location
DC voltage is available between JU-1 (AUX +12 V) and JU-3 (AUX-COM, signal
return). The power available at these terminals is 12 VDC, and maximum current
is 250 mA (3 watts).
The AUX+12 V and AUX-COM terminals can be used to power a relay (3 watts
maximum). Additional fuses are not required, but may be required for some
installations. The default status of AUX+12 V is O
This manual for use by qualified personnel only
AUX Port
.
FF
975-0384-01-02