Inverter/Charger Installation

Network Layout

Charge
Controller
Solar Charge Controller
Figure 2-7 Xantrex Xanbus Network Layout
2–10
Each device on the network is linked with separate lengths of Xantrex Xanbus
cable, as shown in Figure 2-7.
CAUTION: Unpredictable device behavior
Do not connect one end of the network to the other to make a ring.
Two terminators are required to ensure the communication signal quality on the
network. The Xantrex Xanbus-enabled devices at each end of the chain must
have a terminator inserted into their open network ports.
Inverter/Charger
Gri d (AC1 )
In ve rti n g
F l a sh i n g =se l l
Ge n (AC2 )
Fa u l t /
Ch a rg i n g
Wa rn i n g
Eq u a l i ze
Ba tte ry
Hybrid Inverter/Charger
Terminate the network at each end.
This manual for use by qualified personnel only
Automatic Generator Start
System Control Panel
System Control Panel II