Accessing The Ac Terminal Block And Ac Ground Bar - Xantrex XW4024 230 50 Installation Manual

Xw hybrid inverter/charger
Table of Contents

Advertisement

Inverter/Charger Installation

Accessing the AC Terminal Block and AC Ground Bar

2–20
The AC terminal block includes two terminals each (L and Neutral) for AC Grid
input, AC Generator input, and AC Load connections. The neutrals are
connected to each other, requiring only one neutral connection when the
installation uses a Xantrex XW Power Distribution Panel. Without the Xantrex XW
Power Distribution Panel, additional neutral connections may be required at the
input sources.
The AC terminal block is located on the left side of the inverter beneath the AC
access cover. See Figure 2-12.
Recessed
edge
AC Ground Bar
Figure 2-12 AC Terminal Block and Ground Bar
This manual for use by qualified personnel only
Gri d (AC1 )
In ve rti n g
Fl a shi n g = sel l
Ge n (AC2 )
Fa u l t /
Wa rn i n g
Ch a rg i n g
Eq u a l i ze
Ba tte ry
Hybrid Inverter /Charger
AC
AC IN
OUT
N
L
L
N
AC
GRID
LOAD
(AC1)
Remove the two screws on
the AC access cover and
slide it to the left of the
inverter to remove it.
When replacing the AC
access cover, make sure its
recessed edge slips inside
the edge of the front panel.
AC Terminals
AC IN
L
N
GEN
(AC2)
975-0384-01-02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xw4548 230 50Xw6048 230 50

Table of Contents