(2) Original Size Detecting Sensor Adjustment (F7-1)

NOTE
Make this adjustment after any of the following procedures have been performed:
• Memory Clear
• A faulty original size detection occurs
• Replacement of the CCD Unit and Scanner parts (including the Exposure Lamp)
• RAM Board replacement
Adjustment Procedure
1. Stack five sheets of blank A3 or 11" × 17" paper on
the Original Glass and lower the Original Cover.
1167D110AB
2. Call the Tech. Rep. mode to the screen.
3. Touch [Function] to call the Function menu.
4. Touch F7-1 Original Size Detecting Sensor Adjustment.
5. Press the Start key to run the Original Size Detecting Sensor Adjustment function.
NOTE
The Start key remains lit up orange while this function is being run and lights up green as
soon as the sequence is completed.