FrameMaker Ver.5.5E(PC) Di350 TROUBLESHOOTING
98.12.09

(5) C0F32: Faulty E1

C0F33: ATDC Adjustment Failure

ATDC Sensor E1
C0F32, C0F33
Step
1
Are PJ40, CN50, CN17, and PWB-
A PJ15A connected properly?
2
Is the CN50 connection dirty?
3
Is "C0F32" or "C0F33" displayed
even when an I/C with the same T/
C as that of a new one has been
installed?
4
Is "C0F32" or "C0F33" displayed
even when an I/C with the same T/
C as that of a new one has been
installed and an F8 operation run?
(Be sure to record the ATDC control
voltage setting value if an F8 opera-
tion is to be run.)
Relevant Electrical Parts
Check Item
Master Board PWB-A
Result
NO
Connect them properly.
YES
Clean.
NO
Change the I/C with a new one.
YES
Change PWB-A, install the old I/C,
and return the ATDC control voltage
setting to the value recorded. If
"C0F32" or "C0F33" redisplayed,
change the I/C with a new one.
NO
Change the I/C with a new one.
T-40
1171C04TAA
Action