FrameMaker Ver.5.5E(PC) Di350 DIS/REASSEMBLY, ADJUSTMENT
98.12.09
3. Call the Adjust mode to the screen.
4. Touch [IR], [Zoom Adjust], and [FD], in that order.
5. Press the Clear key to clear the current setting.
6. Enter the new setting value from the 10-Key Pad.
Setting Instructions
If the scale on the copy is longer than the actual scale, decrease the setting value.
If the scale on the copy is shorter than the actual scale, increase the setting value.
If the measurement does not fall within the specifications through one setting, try another
setting.
1171D035CA
Setting Value
7. Touch the [END] key to validate the setting value.
Caution
Be sure to touch the END key before returning to normal operating mode. If the Panel
Reset Key is used, the previous setting remains valid.
Use to clear setting value.
Use to enter setting value.
D-49