Single Line Telephones, Analog 500/2500 Sets
The system is compatible with 500 type (Dial Pulse) and 2500 type (DTMF) analog
single line telephones (SLTs). You can install single line telephones as On-Premise or
Off-Premise extensions. Single line telephone users can dial codes to access many of
the features available to multiline terminal users. With single line telephones, you can
have your system simulate PBX operation.
There are 320 single line telephones available (this number may be restricted due to
system power requirements).
When installing single line telephones you must have:
DTMF Dial Out Timer Added
A program is added for DTMF dialing, Program 20-03-07 : System Options for Single
Line Telephones
Program 20-03-03 : System Options for Single Line Telephones – SLT DTMF Dial to
Trunk Lines is set to 0 (receive all digits before sending), the system follows the
timers in Program 20-03-04 and Program 20-03-07.
The timer in Program 20-03-04 System Options for Single Line Telephones – Dial
Sending Start Time for SLT or ARS resets when the user dials another digit.
The timer in Program 20-03-07 does not reset when a digit is dialed. The user must
finish dialing all the digits before this timer expires (entries: 0~64800 seconds,
default: 0).
SLT Adapter
The SLT (Single Line Telephone) Adapter allows a port of a CD-8DLCA, PZ-8DLCB,
CD-16DLCA or CD-LTA to support a single line telephone. A single line telephone
can be connected to the DLC port using the SLT Adapter and 2-wire cable. 64
SLTII(1)-U ADP Single Line Telephone Adapters can be installed in the UNIVERGE
SV8100 system.
SMB8000 Communications Analyst
SMB8000 Communications Analyst is an easy to use, graphically oriented software
package that allows you to monitor and analyze telephone calls, understand
telephone usage, and cut costs. Incoming and outgoing calls are tracked accurately
along with the date and time of the call. When the incoming telephone call must be
tracked with name and/or telephone numbers, SMB8000 Communications Analyst
requires Caller ID service from the local telephone company.
2 - 60
A port on an LCA blade for each single line telephone installed.
If you have 2500 sets, at least one block reserved on the CD-CP00-US for
analog extension DTMF reception.
Trunk Call Dial Forced Sending Start Time (Forced Dial). When