Platform Level Sensor - Genie ZX-135/70 Service Manual

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

August 2014
How to Bleed the Platform
Rotator
Note: Do not start the engine. Use auxiliary power
for all machine functions in this procedure.
1
Rotate the platform full right, then full left until
air is completely out of the rotator. Bleeding
the valve is not necessary.
Part No. 218700
Platform Components
2-4

Platform Level Sensor

The platform level sensor is mounted to the side of
the platform rotator. The platform level sensor is
monitored by the control system to maintain a level
platform through boom range of motion. If a
platform level sensor is replaced, it must be
calibrated prior to machine operation.
How to Calibrate the Platform
Level Sensor
Note: Perform this procedure with the machine on
a firm, level surface.
Note: Perform this procedure with the boom in the
stowed position.
Note: Use the following chart to identify the
description of each LCD screen control button
used in this procedure.
Plus
1
Secure a digital level to one of the side
railings of the platform.
2
Start the machine and level the platform to
gravity. Turn the machine off.
3
Open the ground control box.
ZX-135/70
Service Manual
Minus
Previous
Enter
105