Baud rate / Indication / Terminal
resistance / Interface Settings
SW Pin No.
9-10
11
12
13
14-16
Note
In the factory default settings, the camera address switch is set to 0 and both the ALARM
OUT and POWER indicator switches are set to OFF.
66

Baud rate / Indication / Terminal resistance / Interface Settings

Function
Communication baud rate
switch
ALARM OUT indicator
switch
POWER indicator switch
Termination switch
Communication standard
switch
Description
Set the communication baud rate between the
camera and keypad controller.
Settings for pin 9/10
OFF/OFF: 2400bps, ON/OFF: 4800bps, OFF/
ON: 9600bps, ON/ON: 19200bps
Turn the indicator on or off.
ON: The indicator lights up in orange while the
alarm function is set to on.
OFF: The indicator does not light up.
Turn the indicator on or off.
ON: The indicator lights up in green while the
power is turned on.
OFF: The indicator does not light up.
Set to ON when the unit is connected at the end
of an RS-485 or RS-422 connection. Set to OFF
if it is not connected at the end.
Set the communication standard between the
camera and keypad controller.
Pin 14
ON: RS-422 communication standard
OFF: RS-485 communication standard
Pin 15-16
ON (both Pin 15 and 16) : RS-485 (half-duplex)
communication standard
OFF (both Pin 15 and 16) : RS-485 (full-duplex)/
RS-422 communication standard