WHITE BALANCE (WB)

Main menu → :CAMERA SETUP:
menu
→ :WHITE BALANCE: menu
• 7 white balance modes are available:
ATW/AUTO/ONE PUSH/INDOOR/
OUTDOOR/SODIUM LAMP/
MANUAL.
• ATW mode: white balance ranges form
2000°K to 10000°K.
• AUTO mode: white balance ranges form
3000°K to 7500°K.
• ONE PUSH mode: if you want to use
shortcut key combination (number "73"
+PRESET key) to perform ONE PUSH,
the mode must be set to ONE PUSH first,
and then ONE PUSH function will be
activated.
• INDOOR mode: 3200K is the reference
color temperature.
• OUTDOOR mode: 5800K is the
reference color temperature.
• SODIUM LAMP mode: Sets the white
balance to that suitable for picture under
a high-pressure sodium vapor lamp.
• MANUAL mode: RED and BLUE levels
can be adjusted manually.
Change WB Options
1
Press "95," and then hold the
PRESET key for 3 seconds to enter
the main menu screen.
2
Highlight :CAMERA SETUP:, and
then press the OPEN key to enter the
:CAMERA SETUP: menu.
3
Highlight :WHITE BALANCE:, and
then press the OPEN key to enter the
:WHITE BALANCE: menu.
4
Highlight WB MODE, and then press
the OPEN key to enter the WB mode.
5
Move the joystick up and down to
choose the function to use.
6
Press the OPEN key to confirm, or
press CLOSE to cancel selection and
exit from the menu screen.

NOISE REDUCTION

Image noise can be reduced by using the
NR function. The intensity of the Noise
Reduction filter can be selected among
HIGH, MID and LOW.
Note
By setting level of this function, the image
will appear residual at pan, tilt and zoom
movement. If you do not use this function,
select OFF.