139647_29 GF 370 DV II IPI 10/23
Jøtul GF 370 DV II IPI
Direct Vent Gas Stove
Manufactured and Distributed by:
Jøtul North America
Gorham, Maine USA
Jøtul AS
Fredrikstad, Norway
Test Standards
This appliance complies with National Safety standards
and is tested and listed by Intertek Testing Services of
Middleton, Wisconsin.
In addition, the Jøtul GF 370 DV II IPI has been
tested and listed as a direct vent gas fireplace heater
and listed to ANSI Z21.88-2019 • CSA 2.33-2019 and
CAN/CGA 2.17-M91.
Specifications
Input Rates
Natural Gas
28,000 BTU/hr. maximum input
18,170 BTU/hr. minimum input
Propane
24,000 BTU/hr. maximum input
20,750 BTU/hr. minimum input
Inlet Pressure:
MIN
Natural Gas: 5.0 WC (1.24 kPa)
Propane:
12.0 WC (2.99 kPa) 14.0 WC (3.48 kPa)
Manifold Pressure:
MIN
Natural Gas: 1.6 WC (.398 kPa)
Propane:
6.4 WC (1.59 kPa)
•
Steady State Efficiency: 74.41% NG / 79.30% LP
• AFUE:
68.01% NG / 68.34% LP
•
CSA P4.1-15 Fireplace Efficiency:
71.14 % NG / 64.13% LP
•
Intermittent Pilot Ignition ( IPI )
•
Continuous Pilot Ignition Mode ( CPI or "standing
pilot") is available.
• Power Requirement: 120 VAC for Fan, Lamp, and
Burner Control Module
•
Remote Control Transmitter batteries, 3, AAA - 1.5 v
•
Remote Control Receiver batteries : 4, AA
•
Fan Control Module: 120V / 60 Hz
4
MAX
7.0 WC (1.74 kPa)
MAX
3.5 WC (0.87 kPa)
10.0 WC (2.48 kPa)
Accessories
Traditional Log Set .............................................#156789
River Rocks Set ...................................................#157428
Beachfire Logset ..................................................#158230
Tumbled Stones ................................................. #157243
StarFire Glass Embers, Black ..............................#157342
StarFire Glass Embers, Clear ..............................#156815
Reflective Glass Firebox Liner ............................#156817
Fuel Conversion Kit, Propane - 33% TD ..............#156800
Fuel Conversion Kit, Natural Gas - 33% TD.........#156801
High Altitude Adjustment Kit, NG .......................#156822
Figure 2. Overall dimensions
Safety Screen
Barriers