Fuel Conversion - Jøtul GF 200 DV IPI Installation And Operation Instructions Manual

Gf 200 dv ipi lillehammer direct vent gas stove
Table of Contents

Advertisement

139587_05 GF 200 DV IPI October 2015

Fuel Conversion

The GF 200 DV IPI gas stove is shipped from the factory
equipped to burn NATURAL GAS only. If PROPANE gas is to
be used as fuel, the appliance must first be converted for
using Propane Conversion Kit 157669 included with the
stove. Use Natural Gas Conversion Kit 157670 to change
back for use with natural gas.
THE CONVERSION KIT IS TO BE INSTALLED BY
AN AUTHORIZED JØTUL SERVICE TECHNICIAN
IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTION AND ALL CODES AND
REQUIREMENTS OF THE AUTHORITY HAVING
JURISDICTION. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN SERIOUS
INJURY OR PROPERTY DAMAGE. THE QUALIFIED
AGENCY PERFORMING THIS WORK ASSUMES
RESPONSIBILITY FOR THIS CONVERSION.
THE CONVERSION SHALL BE CARRIED OUT
IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CAN1-B149.1 AND .2
INSTALLATION CODE.
Tools required:
• 1/2" open ended wrench or deep-well socket,
• Torx T20 wrench
• 1/4" socket driver or spade screwdriver
• 7/16" open-end wrench.
Conversion Kit Contents:
• 1, regulator tower labeled for either LP or NG
• 2, regulator tower screws
• 1, burner orifice (1.20mm - LP / 2.10mm - NG)
• Label A - to be completed and applied to
the back of the stove
• Label B - apply to the stove's Rating Plate
• Small valve label - apply to valve body
16
WARNING:
IN CANADA:
Figure 25.
Tilt the burner skirt forward from the rear, then
twist end first out through the door opening.
Figure 26.
Loosen the wing nut and push the shutter stem
fully to the rear to disengage the burner.
Figure 27.
Use a 1/4" socket driver to remove two sheet metal screws
to lift burner out of the firebox.

Hide quick links:

Advertisement

Table of Contents
loading