This conversion kit shall be installed
by a qualified service agency in ac-
cordance with the manufacturer's
instructions and all applicable
codes and requirements of the
authority having jurisdiction. If the
information in these instructions is
not followed exactly, a fire, explo-
sion, or production of carbon mon-
oxide may result causing property
damage, personal injury or loss of
life. The qualified service agency is
responsible for the proper instal-
lation of this kit. The installation is
not proper and complete until the
operation of the converted appli-
ance is checked as specified in the
manufacturer's instructions sup-
plied with the kit.
CAUTION: Before proceeding
with this conversion, the gas sup-
ply must be shut off prior to dis-
connecting the electrical power.

Fuel Conversion

Instructions
Kit 156800 NG to LP
Cet équipement de conversion sera
installé par une agence qualifiée de
service conformément aux instruc-
tions du fabricant et toutes exigences
et codes applicables de l'autorisés
avoir la juridiction. Si l'information
dans cette Instruction n'est pas suivie
exactement, un feu, explosion ou pro-
duction de protoxyde de carbone peut
résulter le dommages causer de pro-
priété, pert ou blessure personnelle
de vie. L'agence qualifiée do service
est esponsable de l'installation pro-
pre de cet équipemetn. L'installation
n'est pas propre et complète jusqu'à
l'operation de l'appareil converi est
chéque suivant les critères établis
dans les instruction de propriétaire
provision nées avel l'équipement.
ATTENTION: Avant de procéder à cette
conversion, l'approvisionnement en
gaz doit être coupée avant de dé-
brancher l'alimentation électrique.
Kit 156801 LP to NG

Advertisement

loading
Need help?

Need help?

Do you have a question about the GF 370 DV and is the answer not in the manual?

Questions and answers

Summary of Contents for Jøtul GF 370 DV

  • Page 1: Fuel Conversion

    Fuel Conversion Instructions Kit 156800 NG to LP Kit 156801 LP to NG This conversion kit shall be installed Cet équipement de conversion sera by a qualified service agency in ac- installé par une agence qualifiée de cordance with the manufacturer’s service conformément aux instruc- instructions and all applicable tions du fabricant et toutes exigences...
  • Page 2 5. Fuel Conversion The GF 370 DV gas stove is shipped from the factory equipped to burn either Natural or Propane gas. Fuel Conversion Kits are available to convert to the alter- nate fuel. The kit contains all the necessary compo-...
  • Page 3 Pilot Head Pilot Orifice Ignitor Flame Sensor Primary Air Shutter Retainer Clip Injector Regulator Diaphragm Regulator Tower Use new Torx screws supplied Figure 4. Fuel conversion components and assemblies 10. Remove the regulator tower and the rubber dia- 7. Change the Pilot Orifice. Pull the Pilot Hood off phragm.
  • Page 4 15. Use an electronic gas detector or soap solution Symptoms of incorrect gas pressure include: to test for leaks at the pilot head and all gas line Insufficient gas pressure: joints. NEVER USE AN OPEN FLAME TO CHECK FOR GAS •...