Important notes
V
ATTENTION!
Always connect the device and the attached peripherals to the same
power circuit. Otherwise you run the risk of losing data if, for example,
a power outage occurs and the central processing unit is still running
but the peripheral device (e.g. a storage subsystem) has failed.
Data cables must be adequately shielded to avoid interference.
For the LAN wiring, the requirements according to standards EN
50173 and EN 50174-1/2 apply. The minimum requirement is the use
of a protected LAN line of category 5 for 10/100 Mbps Ethernet,
and/or of category 5e for Gigabit Ethernet. The requirements of the
specification ISO/IEC 11801 must also be taken into account.
Route the cables in such a way that they do not form a potential
hazard (tripping) and cannot be damaged. When connecting the
device, refer to the relevant notes in the operating manual.
Do not connect or disconnect any data transmission cables during a
thunderstorm (lightning hazard).
Be careful to ensure that no objects (e.g. jewelry, paper clips etc.) or
liquids get inside the device (electric shock, short circuit).
In emergencies (e.g. damaged casing, control elements or cable,
penetration of liquids or foreign bodies), switch off the device immedi-
ately, unplug it from the grounded power outlet, and contact your
customer service center.
Proper operation of the device (in accordance with IEC 60950/EN
60950) is only ensured if the casing is completely assembled and the
rear covers for the installation openings are in place (electric shock,
cooling, fire protection, interference suppression).