BHT-805BWB
[1] Barcode scanning test
Use the following procedure to perform a barcode scanning test.
1.
Select "1: BARCODE" at the TEST menu and then press the ENT
key.
The screen on the right displays.
2.
Scan a barcode with the BHT
Upon completion of barcode scanning, the speaker beeps once, and the
indicator LED turns blue.
3.
The scanned barcode type, number of digits, and data display at the screen. Ensure that the
barcode data and screen display match.
Press the BS/C key to return to the TEST menu.
Barcode Type and Corresponding Characters Displayed on the Screen
Barcode Type
EAN-13, UPC-A
EAN-8
UPC-E
Standard 2of5 (STF)
Interleaved 2of5 (ITF) *
Codabar (NW-7)
Code 39
Code 93
Code 128
GS1-128 (EAN-128)
RSS (GS1 DataBar)
∗ With ITF, a barcode with 4 or more digits is scanned.
92
ID Characters
A
B
C
H
I
N
M
L
K
W
R
Barcode type
Number of digits in the barcode
Barcode data