Error Messages - DURKOPP ADLER 512 Operating Instructions Manual

Hide thumbs Also See for 512:
Table of Contents

Advertisement

Settings via the software
Error message Description
E
8
Table data error Table data could not be read • Save the table data anew.
E
1 0
Seam
appearance
number error
E
3 0
Needle bar
position raised
error
E
4 0
Needle field
area error
E
4 2
Enlargement
error
E
4 5
Seam
appearance
data error
E
5 0
Pause
Operating Manual 512/532 Version 00.0 - 12/2013
5. Use the +/– Function buttons to set the coordinates of the
st
1
stitch for the Y axis.
6. Use the +/– Program buttons to select the next stitch.
7. Repeat steps 3 to 5 for all further stitches.
8. Press the Ready button to save the edited seam appearance.
9. Press the Reset button.
 The button LED goes out.
10. Press the USB button.
 The button LED goes out.

5.23 Error messages

If an error occurs, the Error symbol LED illuminates.
Possible cause
The selected seam
appearance is not stored in
ROM or has been disabled.
Seam appearance "0"
Needle bar is not in the
upper position
Needle field area error
exceeded
Sewing length is less than
10 mm
Seam appearance data
could not be accepted
Reset button pressed while
sewing.
Sewing machine stopped.
Remedy
• Press the Reset button to
confirm the seam
appearance number.
• Check the connections.
• Rotate the needle bar to
the upper dead point.
• Press the Reset button.
• Check the X/Y scaling.
• Press the Reset button.
• Check the seam
appearance and the X/Y
scaling.
• Press the Reset button.
• Check the ROM.
• Press the Reset button.
• Trigger the thread cutter.
• Start the sewing process
anew.
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

532

Table of Contents