Maintenance work
Remove any lint and thread
remnants from the machine upper
section (e. g. using a compressed-
air pistol ).
Control cabinet
60
Figure 15: Cleaning and checking
(1) – Underside of throat plate
Maintenance work:
Explanation
Points that need to be cleaned particularly
thoroughly:
• Area under the throat plate (1)
• Area around the hook (2)
• Bobbin housing and interior
• Thread cutter
• Area around the needle
Keep the fan grill clear
①
(2) – Hook
Operating Manual 512/532 Version 00.0 - 12/2013
Maintenance
②
Operating
hours
8