DURKOPP ADLER 512 Operating Instructions Manual page 57

Hide thumbs Also See for 512:
Table of Contents

Advertisement

Settings via the software
Error message Description
E
5
1 0
Own seam
appearances file
error
E
5
1 1
USB write error
E
5
1 2
USB read error
E
5
1 3
USB write error
E
5
5 0
Data write error
E
5
5 1
Internal process
error
E
7
0
7
Motor signal
7
3
5
error
E
7
3 6
Motor rotation
error
E
7
3 7
Z phase error
E
7
3 8
Z phase error
E
9
0 7
X axis search
error
E
9
0 8
Y axis search
error
E
9
1 0
Clamp foot
search error
E
9
1 1
Clamp foot
motor error
Operating Manual 512/532 Version 00.0 - 12/2013
Possible cause
Read error U01 ~ U10
File with the same name
already present
Data cannot be loaded from
the USB stick
Data cannot be copied to the
USB stick.
Flash memory transfer error • Main power switch OFF.
Software error
Encoder / motor has no
signal
Motor stops after a certain
time / encoder has no signal
Z signal no longer changes
Z signal inaccurate / encoder
has no signal
X axis sensor not responding • Main power switch OFF.
Y axis sensor not responding • Main power switch OFF.
Clamp foot sensor not
responding
Clamp foot motor not
running correctly
Remedy
• Check the file type.
• Store the data anew on
the USB stick.
• Delete or rename the file.
• Check the USB stick.
• Plug in the USB stick
again.
• Check the USB stick.
• Plug in the USB stick
again.
• Repeat the procedure.
• Replace the mainboard.
• Main power switch OFF.
• Repeat the procedure.
• Replace the mainboard.
• Replace the software.
• Check the motor /
encoder.
• Check the motor /
encoder.
• Check the motor /
encoder.
• Check the motor /
encoder.
• Check the sensor.
• Check the sensor.
• Main power switch OFF.
• Check the sensor.
• Main power switch OFF.
• Check the motor and
connections.
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

532

Table of Contents