Error message Description
E
3
0 2
Supper section
error
E
3
0 5
Thread cutter
position error
E
3
0 6
Thread catcher
position error
E
3
3 2
Clamp foot
position error
E
5
0 1
Data read error
E
5
0 2
USB read error
E
5
0 3
SUM read error
E
5
0 4
Endblock error
E
5
0 5
USB read error
E
5
0 6
USB read error
E
5
0 7
Own seam
appearances
read error
E
5
0 8
Own seam
appearances file
error
E
5
0 9
Own seam
appearances file
error
54
Possible cause
Upper section is tilted over.
Thread cutter knife not in the
home position
Thread catcher not in the
home position
Clamp foot not in the home
position
Data not present or stored in
the wrong format
MOT file faulty
CHECKSUM data in MOT
file faulty
No Endblock in the MOT file • Store the Endblock file
USB stick not found
Reading from U01 ~ U10 not
possible.
Read error U01 ~ U10
Read error U01 ~ U10
Read error U01 ~ U10
Operating Manual 512/532 Version 00.0 - 12/2013
Settings via the software
Remedy
• Tilt the upper section
back into place.
• Main power switch OFF.
• Check the sensor.
• Main power switch OFF.
• Check the sensor.
• Main power switch OFF.
• Check the sensor.
• Store the data anew on
the USB stick.
• Store the data anew on
the USB stick.
• Store the CHECKSUM
file anew on the USB
stick.
anew on the USB stick.
• Main power switch OFF.
• Main power switch ON.
• Plug in the USB stick
again.
• Main power switch OFF.
• Main power switch ON.
• Plug in the USB stick
again.
• Download data again.
• Check the file type.
• Check the file type.