ELECTRICAL
STARTING
SYSTEM
ELEC
_
1
Battery fluid specific gravity inspection:
I
! ®Recharge battery
1. Remove caps.
!
i
2. Inspect specific gravity of all celt using Bat- Low specific
Charging
Current:
tery Hydrometer.
jgravity (voltage)J
0.4 amps/10
hrs
NOTE:
Battery
electrolyte
is poisonous
and
Replace the battery if:
dangerous, causing severe burns, etc. it
®Batery voltage will not rise to a
contains sulfuric acid. Avoid contact with
specific value or bubbles fail to
skin,
eyes
or
clothing.
Antidote:
rise even after many hours of
EXTERNAL-Flush with water. INTERNAL-
charging.
Drink
large quantities
of water
or milk.
®Sulfation of one or more cells oc-
Follow with milk of magnesia, beaten egg,
curs, as indicated by the plates
or
vegetable
oil.
Call
a physician
turning white, or an accumula-
immediately,
tion of materiad exists in the bot-
Eyes: Flush with water for 15 minutes and
tom of the cell.
get prompt
medical attention.
Batteries
®Specific gravity readings after a
produce
explosive
gases.
Keep sparks,
long, slow charge indicate on cell
flame,
cigarettes
etc.,
away.
Ventilate
to be lower than the rest.
when charging
or using in an enclosed
®Warpageor buckling of plates or
space.
Always
shield
your
eyes when
insulators is evident.
working
near batteries.
KEEP OUT OF REACH OF CHILDREN.
Specific Gravity:
1.280±0.01 at 20°C (68°F)
If there is not Battery Hydrometer, check bat-
tery voltage using Pocket Tester (YU-03112).
1. Remove battery.
2. Set the Tester selector
to
"DC20V"
position.
3. Connect tester leads to battery terminals.
Tester (+) lead-*(+)
terminal
Tester (-)
iead_
(-)
terminal
_1
Battery Voltage:
12 V or more.
J
6-8