Figure 6A Exhaust port cover
6.3
Fit exhaust port cover (see figure 6A)
Remove four screws from under the top of the
firebox. Fit the exhaust port cover and secure with
the four screws.
7.

VENT OPENING PREPARATION

Important:
This appliance is supplied with a vent unit requiring the
center of the vent hole to be 47
appliance if installed with a pedestal base or 46" above the
bottom of the appliance if installed with legs. This height
must not be reduced by cutting the vertical portion of the
elbow duct. For higher vent openings, one or two optional
vent extension kits #905VEK must be used - See venting
graph figure 1 for the allowable range of heights and
number of extensions required. Before cutting the vent
opening in the wall, make sure that the installed distance
to the bottom of the appliance is known. Once the vent
opening in the wall is cut it will not be possible to alter the
position of the appliance without re-cutting the wall.
7.1
Place dust sheets on the floor and over any
furnishings, etc. in the vicinity.
7.2
Mark the center of the vent hole in the wall.
3
7.3
Cut 8
/
" diameter vent hole through the wall making
8
sure that it is straight and level.
7.4
Place the wall plate with brackets against the inside
face of the wall with the dished projection seated
inside the hole in the wall and the brackets at the
sides.
7.5
Mark the wall plate fixing holes. Remove the plate.
7.6
Drill the plate fixing holes in the wall. Insert wall
plugs if necessary.
7.7
Replace the plate in the wall. Fix the plate to the wall
with four woodscrews.
7.8
Measure the total wall depth from its outside surface
to the finished surface in the room.
7.9
Flatten the outer vent shield tube (For walls thicker
than 24½" a custom shield should be made). The
tube is supplied coiled around the vent terminal unit.
Cut the tube exactly to the total wall depth. Make
sure that the cutting line is at least 1" away from the
nearest bolt hole (see figure 8).
5
/
" above the bottom of the
8
Fig.7 Inside wall plate
Fig. 8 Vent shield tube cutting
7.10
Form the shield into a tube with the holes aligned.
Fasten using the #10 bolts and nuts provided with
the bolt heads outside.
9