8.4.

Rear Vent Outlet Preparation

8.4.1. For Installations With Dura-Vent DV GS Pipes
If installing flat on wall with Valor terminal kit #551DVK, ignore this step :
1.
Fit the Dura-vent adapter #817VAK over the appliance vent collars
pushing on firmly.
Align the adapter so that the seam on horizontal Dura-vent pipes is not at the
bottom – Check by temporarily fitting a Dura-vent pipe.
2.
Drill through the adapter outer tube and appliance outer collar for #6
screws. See figure 39. Make sure that the drill does not penetrate the inner
tubes.
3.
Secure the adapter to the outer collar with two #6 thread cutting screws
supplied (Fig. 39).
8.4.2. For Installations With Dura-Vent DV GS
Co-Linear Liners:
1.
Fit the Dura-vent adapter #817VAK over the appliance
vent collars pushing on firmly.
2.
Fit and fully twist-lock the Dura-vent co-axial to co-
linear connector #923GCL to the #817VAK adapter.
3.
Keeping the connector and adapter fully twist-locked,
rotate them so that the air inlet collar on the connector is at
the bottom. See figure 40.
4.
Drill through the adapter outer tube and appliance outer
collar for #6 screws. See figure 39. Make sure that the drill
does not penetrate the inner tubes.
5.
Secure the adapter to the outer collar with two #6
thread cutting screws supplied (Fig. 39).
Figure 39
Figure 40