Maintenance station

d.
Adjust for bi-directional alignment using the Chapter 9 topic
"Bi-directional print convergence" on page 9-21.
e.
Adjust for temperature offset. Refer to the Chapter 9 topic
"Temperature offset adjustment" on page 9-28.
f.
Adjust the printhead's left and right edge-detection sensors using
the PC-based diagnostics. Refer to the Chapter 9 topic "Sensor
calibration" on page 9-30.
17.
Use the PC-based diagnostics to zero the ink-stick usage count. Refer
to the Chapter 6 topic, "PC-based diagnostics" on page 6-26.
Tools required
#1 POSIDRIV® screwdriver
1.
Turn off the printer. Leave the power cord plugged in to provide a
discharge path for static electricity. Allow the maintenance station to
cool; this takes about 10 minutes.
2.
Remove the right cover as explained in the earlier procedure, "Right
cover" on page 8-4.
Warning
The printhead, maintenance station and drip plate may still be hot.
To avoid injury, allow them to cool before touching them.
3.
Move the printhead to the left away from the printhead's home
position.
4.
Disconnect the air hoses from the air pump.