Welding Parameters - Kemppi FastMig X 450 Operating Manual

Kemppi oy fastmig x 450 welding system operating manual
Hide thumbs Also See for FastMig X 450:
Table of Contents

Advertisement

4.3

Welding parameters

MIG
WFSpeed
WFS-Max
WFS-Min
Voltage
VoltageMax
VoltageMin
Dynamics
1-MIG
EN
WFSpeed
WFS-Max
WFS-Min
FineTuning
FineTuningMax -9...+9
FineTuningMin -9...+9
Dynamics
PULSE MIG
WFSpeed
WFS-Max
WFS-Min
FineTuning
FineTuningMax -9...+9
FineTuningMin -9 ... +9
Dynamics
Pulse Current
14
FastMig X 450
0.7...25 m/min
8...50 V
Step: 0.1
-9...+9
Factory setting is 0 Controls the short circuit behaviour of the arc. The
0.7...25 m/min *
-9...+9
Factory setting is 0
( = curve point)
Step: 0.5
Step: 0.5
-9...+9
Factory setting is 0 Controls the short circuit behaviour of the arc. The
0.7...25 m/min *
-9...+9
Factory setting is 0
( = curve point)
Step: 0.5
Step: 0.5
-9...+9
Factory setting is 0 Controls the short circuit behaviour of the arc. The
-10...+15%
Factory setting
is 0 %
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min,
and by 0.1, when WFSpeed > 5 m/min
Sets the limit for maximum WFSpeed
Sets the limit for minimum WFSpeed
Controls the length of the arc
Sets the limit for maximum voltage value
Sets the limit for minimum voltage value
lower the value the softer the arc is. The higher the
value the rougher the arc is.
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/
min, and by 0.1, when WFSpeed > 5 m/min
Sets the limit for maximum WFSpeed
Sets the limit for minimum WFSpeed
Adjusts the arc voltage of the curve (arc length)
within certain limits
Sets the limit for maximum arc length
Sets the limit for minimum arc length
lower the value the softer the arc is. The higher the
value the rougher the arc is.
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed
< 5 m/min, and by 0.1, when WFSpeed > 5 m/min
Sets the limit for maximum WFSpeed
Sets the limit for minimum WFSpeed
Adjusts the base current of the curve (arc length) in
certain limits
Sets the limit for maximum arc length
Sets the limit for minimum arc length
lower the value the softer the arc is. The higher the
value the rougher the arc is.
Reduces (–) or raises (+) the pulse current of the
curve

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents