Kemppi FastMig X 450 Operating Manual page 17

Kemppi oy fastmig x 450 welding system operating manual
Hide thumbs Also See for FastMig X 450:
Table of Contents

Advertisement

DOUBLE PULSE MIG
WFSpeed
0.7...25 m/min *
WFS-Max
WFS-Min
FineTuning
-9...+9
FineTuningMax -9...+9
FineTuningMin -9...+9
Dynamics
-9...+9
Pulse Current
-10...+15%
DPulseAmp
0.1...3.0 m/min
DPulseFreq
0.4...8.0 Hz
WISEROOT+
WFSpeed
1.5...8.0 m/min *
WFS-Max
WFS-Min
FineTuning
-9...+9
FineTuningMax -9...+9
FineTuningMin -9...+9
* Different welding programs may further restrict the value range.
MMA PROCESSES
Current
14...450 A
CurrentMax
14...450 A
CurrentMin
14...450 A
ArcForce
-9...+9
StartPower
-9...+9
© Kemppi Oy / 1312
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/
min, and by 0.1, when WFSpeed > 5 m/min
Sets the limit for maximum WFSpeed
Sets the limit for minimum WFSpeed
Factory setting is 0
Adjusts the base current of the curve (arc length) in
( = curve point)
certain limits
Step: 0.5
Sets the limit for maximum arc length
Step: 0.5
Sets the limit for minimum arc length
Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
Factory setting
Reduces (-) or raises (+) the pulse current of the
is 0%
curve
Factory setting is
Adjusts the amplitude of the WFSpeed by steps of
CURVE
0.1. Value comes from welding program.
Factory setting is
Adjusts the frequency of the double pulse by steps of
CURVE
0.1. Value comes from welding program.
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/
min, and by 0.1, when WFSpeed > 5 m/min
Sets the limit for maximum WFSpeed
Sets the limit for minimum WFSpeed
Adjusts the base current of the curve (heat of the
arc) within certain limits.
Step: 0.5
Sets the limit for maximum heat of the arc
Step: 0.5
Sets the limit for minimum heat of the arc
Welding current
Set the limit for maximum current value
Set the limit for minimum current value
Factory setting
Controls the short circuit behaviour of the arc. The
is 0
lower the value the softer the arc is. The higher the
value the rougher the arc is.
Factory setting
Adjusts arc ignition
is 0