4.3

Welding parameters and functions

4.3.1 Welding parameters

MIG
WFSpeed
WFS-Max
WFS-Min
Voltage
VoltageMax
VoltageMin
Dynamics
1-MIG
WFSpeed
WFS-Max
WFS-Min
FineTuning
FineTuningMax
FineTuningMin
Dynamics
PULSE MIG
WFSpeed
WFS-Max
WFS-Min
FineTuning
FineTuningMax
FineTuningMin
Dynamics
Pulse Current
© Kemppi Oy / 1515
0.7 – 25 m/min
8.0 – 50.0V
0.1V steps
-9 ... +9
Factory setting is 0
0.7 – 25 m/min *
-9.0 ... +9.0
Factory setting is 0.0
( = curve point)
0.5 steps
-9.0 ... +9.0
0.5 steps
-9.0 ... +9.0
0.5 steps
-9 ... +9
Factory setting is 0
0.7 – 25 m/min *
-9.0 ... +9.0
Factory setting is 0.0
( = curve point)
0.5 steps
-9.0 ... +9.0
0.5 steps
-9.0 ... +9.0
0.5 steps
-9 ... +9
Factory setting is 0
-10% ... +15%
Factory Setting
is 0%
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
Set the limit for maximum WFSpeed
Set the limit for minimum WFSpeed
Controls the length of the arc
Set the limit for maximum voltage value
Set the limit for minimum voltage value
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
Set the limit for maximum WFSpeed
Set the limit for minimum WFSpeed
Adjusts the arc voltage of the curve within certain
limits. In other words, it adjusts the length of the arc
within certain limits
Set the limit for maximum arc length
Set the limit for minimum arc length
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
Set the limit for maximum WFSpeed
Set the limit for minimum WFSpeed
Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.
Set the limit for maximum arc length
Set the limit for minimum arc length
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%.