    This operating manual contains important information on the use, maintenance and safety of your Kemppi product. The technical specifications of the equipment can be found at the end of the manual.
  • Page 6: Use

    FastMig MS 200 and MS 300 control panels are designed to be used only with synergic power sources FastMig M 320, 420, or 520. MS 200 panel can be mounted to MXF 63 (200 mm wire spool) wire feeder and MS 300 panel to MXF 65 and 67 (300 mm wire spool) wire feeders.
  • Page 7: Functions Of Ms 200 And Ms 300 Panels

    **) Wise products are available as optional welding process solutions. Not included in the standard delivery. Please visit www.kemppi.com or Kemppi Datastore. With MS 200 and MS 300 panels ‘Wire Inch’ and ‘Gas Test’ buttons should be used from the NOTE! inside of the wire feed unit.
  • Page 8: Ms 200 And Ms 300 Operations

    If the LED (14) is lit, liquid-cooling is activated in the system. In this case, ensure that you have connected a liquid-cooled MIG gun to the equipment. The cooling units starts on the next machine startup. FastMig MS 200, MS 300...
  • Page 9 Minilog: Minilog is an additional function, which can be purchased separately. (Minilog is also referred as 'Matchlog' in DataStore.) Without Minilog license, press of the button chooses between 2T and 4T. © Kemppi Oy / R03...
  • Page 10 2T/4T, Creep Start, and Crater Level are recorded in the memory as well as the used welding program. Short press selects the memory locations. Long press saves the current settings to the selected memory location. FastMig MS 200, MS 300...
  • Page 11: Additional Welding Functions

    When the gun switch is pressed down in connection with termination of welding, the welding power drops to the crater-filling level selected previously. The crater filling function is discontinued by releasing the gun switch. © Kemppi Oy / R03...
  • Page 12 • MatchLog™ contains MiniLog™ function for quickly changing welding parameters on the run. It is an optional feature, which can be purchased through Kemppi DataStore. • If your welding needs change and you wish to update your system in the future, you can order additional welding programs or other welding software and load them to your system with Kemppi DataGun field programming device.
  • Page 13: Fastmig Welding Programs

    CrNi 23 12 Ar+2%CO₂ CrNi 23 12 Ar+2%CO₂ CrNi 23 12 Ar+2%CO₂ CrNi 23 12 Ar+30%He+1%O₂ CrNi 23 12 Ar+30%He+1%O₂ CrNi 23 12 Ar+30%He+1%O₂ CrNi 23 12 Ar+30%He+1%O₂ FC-CrNiMo 19 12 Ar+18%-25%CO₂ FC-CrNiMo 19 12 Ar+18%-25%CO₂ © Kemppi Oy / R03...
  • Page 14 Al group Wire (mm) Material Shielding gas AlMg5 AlMg5 AlMg5 AlSi5 AlSi5 AlSi5 SPE group Wire (mm) Material Shielding gas CuSi3 CuSi3 CuSi3 CuSi3 CuSi3 Ar+2% CO₂ CuSi3 Ar+2% CO₂ CuSi3 Ar+2% CO₂ CuAl8 CuAl8 CuAl8 FastMig MS 200, MS 300...
  • Page 15 Backing gas CuSi3 CuAl8 *) WiseRoot and WiseThin welding processes are not included in the standard delivery. They are available as optional welding process solutions. Please visit www.kemppi.com or Kemppi Datastore. More welding programs are available in Kemppi DataStore. NOTE!
  • Page 16: Panel Ms 200 And Ms 300 Setup Parameters

    Wise Penetration On OFF, on Switch Wise Penetration on/off (only in 1-MIG) Penetration Level -30 ... +30% Set the arc length where penetration control begins (only in 1-MIG) MiniLog On on, OFF Switch on/off MiniLog FastMig MS 200, MS 300...
  • Page 17 OFF: Display shows pole voltage (not in WiseRoot or WiseThin) Cable Length std, 5 – 80m Cable loss is calculated for optimal arc control and for the Arc Voltage display (not in WiseRoot or WiseThin) © Kemppi Oy / R03...
  • Page 18 Restore Factory OFF, PAn, ALL Control panel reset function. Settings OFF = No reset PAn = Settings will be restored, but memory channels remain unchanged ALL = All settings will be restored to factory values. FastMig MS 200, MS 300...
  • Page 19 Settings memory channels remain unchanged ALL = All settings will be restored to factory values In these setup lists following functions needs activation (Err 171): NOTE! • Minilog • Panel Locking • WisePenetration • WiseFusion © Kemppi Oy / R03...
  • Page 20: Fastmig Error Codes

    Gas is unconnected to the wire feeder. Gas has been ran out, gas hose is leaking or there is no pressure enough in the gas web. Connect the gas to the wire feeder, check gas hose and the pressure of the gas web. FastMig MS 200, MS 300...
  • Page 21: Disposal

    The owner of the equipment is obliged to deliver a decommissioned unit to a regional collection centre, per the instructions of local authorities or a Kemppi representative. By applying this European Directive you will improve the environment and human health.
  • Page 22 www.kemppi.com...