This operating manual contains important information on the use, maintenance and safety of your Kemppi product. The technical specifications of the equipment can be found at the end of the manual.
FastMig MS 200 and MS 300 control panels are designed to be used only with synergic power sources FastMig M 320, 420, or 520. MS 200 panel can be mounted to MXF 63 (200 mm wire spool) wire feeder and MS 300 panel to MXF 65 and 67 (300 mm wire spool) wire feeders.
**) Wise products are available as optional welding process solutions. Not included in the standard delivery. Please visit www.kemppi.com or Kemppi Datastore. With MS 200 and MS 300 panels ‘Wire Inch’ and ‘Gas Test’ buttons should be used from the NOTE! inside of the wire feed unit.
If the LED (14) is lit, liquid-cooling is activated in the system. In this case, ensure that you have connected a liquid-cooled MIG gun to the equipment. The cooling units starts on the next machine startup. FastMig MS 200, MS 300...
Page 10
2T/4T, Creep Start, and Crater Level are recorded in the memory as well as the used welding program. Short press selects the memory locations. Long press saves the current settings to the selected memory location. FastMig MS 200, MS 300...
Page 12
• MatchLog™ contains MiniLog™ function for quickly changing welding parameters on the run. It is an optional feature, which can be purchased through Kemppi DataStore. • If your welding needs change and you wish to update your system in the future, you can order additional welding programs or other welding software and load them to your system with Kemppi DataGun field programming device.
Page 14
Al group Wire (mm) Material Shielding gas AlMg5 AlMg5 AlMg5 AlSi5 AlSi5 AlSi5 SPE group Wire (mm) Material Shielding gas CuSi3 CuSi3 CuSi3 CuSi3 CuSi3 Ar+2% CO₂ CuSi3 Ar+2% CO₂ CuSi3 Ar+2% CO₂ CuAl8 CuAl8 CuAl8 FastMig MS 200, MS 300...
Page 15
Backing gas CuSi3 CuAl8 *) WiseRoot and WiseThin welding processes are not included in the standard delivery. They are available as optional welding process solutions. Please visit www.kemppi.com or Kemppi Datastore. More welding programs are available in Kemppi DataStore. NOTE!
Wise Penetration On OFF, on Switch Wise Penetration on/off (only in 1-MIG) Penetration Level -30 ... +30% Set the arc length where penetration control begins (only in 1-MIG) MiniLog On on, OFF Switch on/off MiniLog FastMig MS 200, MS 300...
Page 18
Restore Factory OFF, PAn, ALL Control panel reset function. Settings OFF = No reset PAn = Settings will be restored, but memory channels remain unchanged ALL = All settings will be restored to factory values. FastMig MS 200, MS 300...
Gas is unconnected to the wire feeder. Gas has been ran out, gas hose is leaking or there is no pressure enough in the gas web. Connect the gas to the wire feeder, check gas hose and the pressure of the gas web. FastMig MS 200, MS 300...
The owner of the equipment is obliged to deliver a decommissioned unit to a regional collection centre, per the instructions of local authorities or a Kemppi representative. By applying this European Directive you will improve the environment and human health.
Need help?