TECHNICAL DATA

FastMig™ X 450
Connection voltage
Rated power
Connection cable
Fuse (delayed)
Output 40 °C
Welding current and voltage range
Max. welding voltage MMA
Open circuit voltage
Open circuit power
Power factor at max. current
Efficiency at 100 % ED
Operating temperature range
Storage temperature range
EMC class
Minimun short circuit power S
Degree of protection
External dimensions
Weight
Voltage supply for auxiliary devices
Fuse (delayed)
Voltage supply for cooling unit
The minimum recommended generator output is 35 kVA.
* See section 2.2: Distribution network.
© Kemppi Oy / 1312
3~50/60 Hz
60 % ED
100 % ED
HO7RN-F
60 % ED
100 % ED
MMA
MIG
MMA
MIG/MAG/Pulse
of supply network*
sc
L x W x H
400 V, -15...+20 %
22.1 kVA
16.0 kVA
4G6 (5 m)
35 A
450 A
350 A
15 A/20 V – 450 A/46 V
20 A/12 V – 450 A/46 V
46 V
U
= 70 – 98 V
0
U
= 50 V
av
U
= 80 – 98 V
0
100 W
0.88
87 %
-20...+40 °C
-40...+60 °C
A
5.5 MVA
IP23S
590 x 230 x 430 mm
38 kg
50 V DC / 100 W
6.3 A
24V DC / 50 VA
EN
27