Kemppi FastMig X 450 Operating Manual page 21

Kemppi oy fastmig x 450 welding system operating manual
Hide thumbs Also See for FastMig X 450:
Table of Contents

Advertisement

Control *
RemoteAutoRecog ON, OFF.
MIG CurrentDisp
WFMotorWarnLev 1.5...5.0 A
WF End Step
AutoWireInch
Gas Guard
* When connecting a remote control device to the power source in MMA/CC/CV welding,
you don't need to make adjustments to this setting. Remote control device is automatically
recognised, when USER option is selected (default) and RemoteAutoRecog=ON.
© Kemppi Oy / 1312
USER, PANEL,
Factory settings is USER
REMOTE, GUN.
Factory setting is ON
ON, OFF
Factory setting is OFF
Factory setting is 3.5A
ON, OFF
Factory setting is OFF
ON, OFF
Factory setting is ON
ON, OFF
Factory setting is OFF
This setting affects the XF 37 control
panel remote control unit selection.
USER: User can select the remote control
device at XF 37 panel
PANEL: Selection is locked to PANEL, and
user can not select the remote device at
XF 37 panel.
REMOTE: Selection is locked to HAND
REMOTE device.
GUN: Selection is locked to GUN REMOTE
device.
Automatic remote control unit
recognition.
ON: Remote control units are
recognized. Wire feeder panel XF 37
jumps to PANEL selection, if the selected
remote control unit disappears.
OFF: Remote control units are not
recognized. Remote control unit
selection remains unchanged if the
selected remote control unit disappears.
ON: Displays amperage (A) preset values
OFF: Displays wire feed speed (m/min).
The alarm level of wire feed motor
current.Check/service wire feed
mechanism, adjustment and gun
components.
ON: The filler wire steps forward at the
end of the welding cycle.
OFF: Filler wire remains static at the end
of the welding cycle.
Automatic SuperSnake Wire Inch
feature. When ON, the Wire Inch button
drives the filler wire automatically up to
SuperSnake.
Turns the gas guard on and off, provided
that one is installed.
EN
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents