Memory Functions (Only With The Pulse Panel); Calling The Values From The Memory; Saving A Welding Situation (Parameters) In The Memory; Code Locking - Kemppi MASTERTIG AC/DC 2000 Operation Instructions Manual

Hide thumbs Also See for MASTERTIG AC/DC 2000:
Table of Contents

Advertisement

3.5.

MEMORY FUNCTIONS (ONLY WITH THE PULSE PANEL)

By means of the memory functions you can save 9 panel settings in the permanent memory. All
adjustable or chosen values are saved in the memory. When the memory function is not in use, the
numerical display of the memory section is black.
With the CHANNEL key you can select the channel to be read and used for the saving of a setting.
The MEM / PANEL key is used to select whether to use the values in the memory or values control-
led from the panel.
The function of the SAVE key is two-phased. When you press it once, you select the values to be
saved. In this case the light SAVING is blinking to show that you are performing a saving operation.
When the light is blinking, you can find the channel into which you want to save the values. When
you press the key again, the information is saved in the memory.

3.5.1. Calling the values from the memory

1. Press the CHANNEL key so many times that the numerical channel display shows the
number of the channel that you want. At the same time, the signal lights of the panel show
you the selections of the selected channel and the current display shows you the set value
of the current. You can see the other values of the welding parameters
by pressing the parameter key or by turning the potentiometer. All the
MEM.
SAVING
PANEL
values are locked, which means that you cannot change them while the
MEM signal light is on.
2. If you want to change the values found, press the MEM / PANEL key
PANEL
MEM.
SAVING
and the PANEL signal light comes on and you can change the values.

3.5.2. Saving a welding situation (parameters) in the memory

You have good welding values, which you want to save in the memory.
1. Press the SAVE key once and the SAVING light starts to blink.
PANEL
MEM.
SAVING
2. Press the CHANNEL key so many times that the number of the channel
in which you want to save the values is shown in the numerical display.
MEM.
SAVING
PANEL
3. Now press the SAVE key again and the values are saved in the memory.
MEM.
SAVING
PANEL
Note! When you are saving (= the SAVING light is blinking) and you have rolled the number of
the channel that you want by using the CHANNEL key, you can see the previous values of that
channel by pressing the MEM / PANEL key to bring the panel to the MEM status, so that you
can check the present values of that channel. In this case the values to be saved will not change.
After the check, press the MEM / PANEL key again and you can again see the values to be
saved and you can save them by pressing SAVE.
3.6.

CODE LOCKING

The welding machine has a theft protection. You can install a three-digit machine-specific code
into the machine, which the user must know in order to turn the machine on. The code is saved
in the panel. If you change the panel the code follows the panel.
When the machine leaves the factory, the code locking operation is not on.
20 – Mastertig AC/DC 2000, 2500, 2500W, 3500W/0510
©
COPYRIGHT KEMPPI OY

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents