(9) Remove the actuator F.
(10) Release the lock of the connector, remove the cable from the panel PCB ASSY, and
then remove the FPC key.
NOTE:
• After disconnecting flat cable(s), check that each cable is not damaged at its end or
short-circuited.
• When connecting flat cable(s), do not insert them at an angle. After insertion, check
that the cables are not at an angle.
Control panel ASSY
Paper feed chute
Actuator F
Fig. 4-31
Fig. 4-32
4-19
2
1
Cable
Cable
Panel PCB ASSY
MFC-8220
SERVICE MANUAL
FPC key