Wsw10 Protocol Definition - Brother MFC-8220 Service Manual

Table of Contents

Advertisement

APPENDIX 3 FIRMWARE SWITCHS (WSW)
Selector
No.
1
2
3
4
5
6
7
8
l
Selector 2:
This selector sets the time length from when the machine transmits the last dial digit until the
CML relay comes on.
l
Selector 3:
This selector sets the time length until the machine transmits a CNG after it turns on the CML
relay.
l
Selector 4:
This selector sets the time length until the machine transmits a CED after it turns on the CML
relay. This setting does not apply to switching between facsimile and telephone.
l
Selectors 5 and 6: No. of training retries
These selectors set the number of training retries to be repeated before automatic fallback.
l
Selectors 7 and 8: Encoding system (Compression)
This selector determines whether or not use of the MR/MMR coding system will be allowed.
WSW10 (Protocol definition 2)
Function
Not used.
Time length from transmission of
the last dial digit to CML ON
Time length from CML ON to CNG
transmission
Time length from CML ON to CED
transmission (except for facsimile-
to-telephone switching)
No. of training retries
Encoding system
(Compression)
Time length from transmission of the last dial digit to CML ON
Time length from CML ON to CNG transmission
Time length from CML ON to CED transmission
Setting and Specifications
0: 100 ms
0: 2 sec.
0: 0.5 sec.
No.
5
6
0
0
0
1
1
0
1
1
MR
0: Allowed
MMR
0: Allowed
A-16
1: 50 ms
1: 4 sec.
1: 2 sec.
:
1 time
:
2 times
:
3 times
:
4 times
1: Not allowed
1: Not allowed

Hide quick links:

Advertisement

Table of Contents
loading