Selector
No.
1
Not used.
2
3
Time length from CML ON to
start of pseudo ring backtone
4
transmission
5
|
Not used.
8
l
Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring backtone
transmission.
Selector
No.
1
|
Not used.
4
5
Pause between paging number
|
and PIN
7
8
Not used.
l
Selectors 5 through 7:
These selectors set the pause time between a telephone number being paged and PIN
(private identification number) for the paging feature.
WSW24 (TAD setting 2)
Function
WSW25 (TAD setting 3)
Function
Pause between paging number and PIN
A-29
Setting and Specifications
No.
3
4
0
0
:
4 sec.
0
1
:
3 sec.
1
0
:
2 sec.
1
1
:
1 sec.
Setting and Specifications
No. 5
6
7
0
0
0
:
0
0
1
:
0
1
0
:
0
1
1
:
1
0
0
:
1
0
1
:
1
1
0
:
1
1
1
:
MFC-8220
SERVICE MANUAL
2 sec.
4 sec.
6 sec.
8 sec.
10 sec.
12 sec.
14 sec.
16 sec.