Table of Contents

Advertisement

APPENDIX 3 FIRMWARE SWITCHS (WSW)
Selector
No.
1
2
3
4
5
6
7
8
Selector 2:
This selector sets the default reduction rate to be applied if the automatic reduction function
fails to record one-page data sent from the calling station in a single page of the current
recording paper.
If it is set to "0," the machine records one-page data at full size (100%) without reduction; if it
is set to "1," the machine records it at the size* specified according to the current paper size.
Selector 5:
The ringer pattern consists of short and long rings, e.g., short-short-long rings. This selector
sets the minimum OFF duration following a short ring in order to avoid missing ringer tones
in distinctive ringing.
If this selector is set to "1," when the short-OFF duration is a minimum of 90 ms long, then
the machine will interpret the short-OFF as OFF.
Selector 8:
This selector determines whether or not the "CHANGE DRUM SOON" message should
appear on the LCD when the service life of the laser-sensitive drum in the laser unit will
expire soon.
WSW31 (Function setting 9)
Function
Not used.
Default reduction rate for failure of
automatic reduction during
recording
Not used.
Minimum short-OFF duration in
distinctive ringing
Not used.
"CHANGE DRUM SOON"
message
Default reduction rate for failure of automatic reduction during recording
Minimum short-OFF duration in distinctive ringing
"CHANGE DRUM SOON" message
Setting and Specifications
0: ON
0: 130 ms
0: Yes
A-34
1: OFF
1: 90 ms
1: No

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents