CHAPTER 4 DISASSEMBLY AND RE-ASSEMBLY
3.5

Access Cover / Battery ASSY

(1) Remove the access cover.
(2) Loosen the two access plate screws.
(3) Remove the access plate.
(4) Disconnect the connector of the battery ASSY.
!
CAUTION:
• There is a danger of explosion if the battery is incorrectly replaced.
• Use Brother genuine spare part when you replace the battery.
• Do not disassemble, recharge or dispose of in fire.
• Used battery should be disposed of according to local regulations.
Access plate
Battery ASSY
Access plate screw
Access cover
Hooks
Access plate
Hooks
Hooks
Access plate
screw
Hooks
Fig. 4-22
Main PCB ASSY
Fig. 4-23