APPENDIX 3 FIRMWARE SWITCHS (WSW)
Selector
No.
1
|
3
4
5
|
8
NOTE:
WSW41 takes effect only in the V. 34 mode.
Selectors 1 through 3 are applicable only to models equipped with a flat-bed scanner.
l
Selectors 1 through 3: ON-duration of the fluorescent lamp built in the CIS unit (Not used.)
If the scanning operation is started when the fluorescent lamp is off, then the lamp will come
on for scanning. These selectors determine how long the lamp will stay ON after scanning.
If these selectors are set to "1, 1, 1," the fluorescent lamp will go off after the scanning
sequence.
l
Selectors 5 through 8:
These selectors are used to adjust the transmitting level of the modem when the reception
level at the remote station is improper due to line loss. This function applies to super G3
protocol signals.
WSW41 (Function setting 19)
Function
ON-duration of the fluorescent lamp
built in the CIS unit (Not used.)
Broadcast report via e-mail
Modem attenuator
Modem attenuator
Setting and Specifications
No. 1 2 3
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
0: ON
No. 5
6
0
0
0
0
0
0
0
0
0
1
1
1
A-42
:
16 hours
:
24 hours
:
12 hours
:
8 hours
:
4 hours
:
2 hours
:
10 minutes
:
0 minute
1:
OFF
7
8
0
0
:
-10 dBm
0
1
:
-11 dBm
1
0
:
-12 dBm
1
1
:
-13 dBm
0
0
:
-14 dBm
|
|
1
1
:
-25 dBm