Alarm Input/Output; Alarm Input - Lorex LN Series Instruction Manual

Ln series remote surveillance internet camera
Table of Contents

Advertisement

Alarm Input/Output

ATTENTION: This section is applicable to LNZ4001 camera models
Configure Alarm Input settings for an external alarm/sensor (not included) and Alarm Output
settings for an external alarm light/siren (not included).

Alarm Input

To configure alarm input settings:
1. Connect a 12V external alarm sensor (i.e.
motion sensor), to the Input ports of the alarm
block on the rear panel of the camera.
2. Open DigiViewer and click Events
Input/Output.
3. Under Alarm Input, select the box, Enable
Sensor Input 1.
4. Under Trigger Condition, select High for a
Normally Open circuit (NO) or Low, for a
Normally Closed circuit (NC).
5. Under Camera Move, select a preset from the
Select Pos. drop-down menu. When an external alarm or sensor is triggered, the PTZ camera
will turn to the position of the selected preset.
Figure 18.8 Alarm input
6. Click Submit In/Output to save your settings.
SENSOR
>
Alarm
Figure 18.7 Alarm input
only
.
Alarm
Events
Ground
67