2.1.3 Pin Assignments for the 6-pin Micro-Miniature Receptacle

The power input connector on the camera is a Hirose 6 pin, micro-miniature, push-pull locking
receptacle (part # HR10A-7R-6PB) or the equivalent. The power supply should deliver 12 V at a
minimum of 1.5 A with a voltage accuracy of ±10%. The pin assignment of the plug is given in
Table 2-3.
Pin
Number
1
1, 2
3, 4
2
5, 6
1
Pins 1, and 2 are tied together inside of the camera.
2
Pins 5, and 6 are tied together inside of the camera.
Table 2-3: A400k Pin Assignments for the 6-pin Micro-miniature Receptacle
The recommended mating connector is the Hirose micro-miniature locking plug (part # HR10A-
7P-6S). A plug of this type will be shipped with each camera. The plug should be used to terminate
the cable on the power supply for the camera.

2.1.4 Pin Assignments for the 4-pin Micro-Miniature Receptacle

The flash trigger output connector type is a micro-miniature push-pull locking connector, the
Hirose HR10A-7R-4S. The receptacle provides a TTL signal for an external flash. This signal can
be programmed to be deactivated, tied to a flash window signal generated internally, tied to the
external ExFlash input, and it can be permanently on (see Section 2.5.8). Figure
timing diagram.
It can be set to high impedance (default setting) so that the flash trigger is disabled or, it can be
selected to be to TTL Active High, Low Side Switch (Open Collector), or High Side Switch. Figure
2-4
shows the three variants of output schematics of the flash trigger connector.
The pin assignment is given in Table 2-4.
Pin
Number
2
1, 3
4
Table 2-4: A400k Pin Assignments for the 4-pin Micro-miniature Receptacle
The recommended mating connector is the Hirose HR10A-7P-4P.
The flash trigger signal is short-circuit proof. Insulation voltage is 100 V.
Basler A400k
Signal
Direction
Name
+12 VDC
Input
-
-
DC Gnd
Input
Signal
Direction
Name
Flash Trigger
Output
-
-
DC Gnd
Output
DRAFT
Level
Function
12 VDC ± 10%
Camera power input
-
Not connected
Ground
DC ground
Level
Function
TTL signal
Flash trigger; the HIGH signal is current limited
to 50 mA ±20%.
-
Not connected
Ground
DC ground