Area Of Interest Setup Rules; Setting The Area Of Interest - Basler A400K User Manual

Basler a400k
Table of Contents

Advertisement

3.8.1 Area of Interest Setup Rules

When setting up the area of interest, observe the following rules:
• Starting columns can only be selected in multiples of 16 (+1), that is, the starting column can
be 1, 17, 33, and so on.
• The width can only be multiples of 16, that is, 16, 32, 48, and so on.
• The sum of the setting for the starting column plus the setting for the width in columns can
not exceed 2353.
• The sum of the setting for the starting line plus the setting for the height in lines can not
exceed 1727.

3.8.2 Setting the Area of Interest

You can set the area of interest by using the Camera Configuration Tool Plus (CCT+), by using
binary write commands from within your own application to set the camera's control and status
registers (CSRs) or by using the AOI Editor.
With the CCT+
With the CCT+ (see Section 4.1), you use the AOI Starting Column, AOI Width, AOI Starting Line,
and AOI Height settings in the Area of Interest parameters group to set the area of interest.
By Setting CSRs
You can set the AOI starting column by writing a value to the Starting Column field of the AOI
Starting Column CSR (see page 4-25).
You can set the AOI width by writing a value to the Width field of the AOI Width CSR (see page
27).
You can set the AOI starting line by writing a value to the Line field of the AOI Starting Line CSR
(see page 4-28).
You can set the AOI height by writing a value to the Height field of the AOI Height CSR (see page
4-29).
See Section
4.2.2
write commands.
With the AOI Editor
You can set an AOI using the AOI Editor (see Section 3.8.4.2). This involves entering the settings
of one AOI in the AOI list of the AOI Editor.
Basler A400k
DRAFT
for an explanation of CSRs. See Section
Basic Operation and Features
4.3.1
for an explanation of using read/
4-