Clock Model Status Values; Constellation Change Flag Values - Novatel EuroPak-15a User Manual

Table of Contents

Advertisement

Data Logs
Recommended Input:
LOG CLOCKMODELA ONTIME 1
Example Output:
#CLOCKMODELA,COM1,0,55.0,FINE,1048,497224.500,
00000128,879E,0;VALID,0,497224.500,497224.500,6.59596736E-01,-
9.29232987E-02,-3.40165918E+00,4.63006778E+02,1.19966616E+00,-
4.50054493E+02,1.19966616E+00,2.15673338E-01,-7.90256149E-01,-
4.50054493E+02,-7.90256149E-01,4.76057122E+02,-2.902,-1.03659974E-
01,FALSE*f33b4465
VALID
CONVERGING
ITERATING
INVALID
ERROR
FALSE
TRUE
EuroPak-15a Receiver User Manual Rev 5
Table 36: Clock Model Status Values
ASCII
Binary
0
1
2
3
4
Table 37: Constellation Change Flag Values
ASCII
Binary
0
1
Description
The clock model is valid
The clock model is near validity
The clock model is iterating towards validity
The clock model is not valid
Clock model error
Description
There has not been a change in the constellation
The constellation has changed