Agcstats Automatic Gain Control Status - Novatel EuroPak-15a User Manual

Table of Contents

Advertisement

Chapter 6
6.3.1

AGCSTATS Automatic Gain Control Status

This log provides status information for the automatic gain control mechanism and details of the parameters it
is currently using.
Log Type: Synch
Field
Field
Name
1
header
2
# RF decks
3
AGCword
4
gain
5
pulse width
6
modulus
7
bin1
8
bin2
9
bin3
10
bin4
11
bin5
12
bin6
13
noise floor
14
Reserved
15
16...
Next RF deck, offset = H+ 4 + (#RF *88) Bytes
32-bit CRC (ASCII and Binary only)
72
Data Description
This field contains the message header, in ASCII or Binary format.
See Section 4.3 on Page 35.
Number of RF decks reported in this message.
AGC status word (see Table 35 on Page 73)
AGC gain (0 to 99999)
VARF pulse width
VARF modulus
A/D bin 1 (decimal percentage)
A/D bin 2 (decimal percentage)
A/D bin 3 (decimal percentage)
A/D bin 4 (decimal percentage)
A/D bin 5 (decimal percentage)
A/D bin 6 (decimal percentage)
Calculated noise floor
Format
Ulong
Ulong
Ulong
Ulong
Ulong
Double
Double
Double
Double
Double
Double
Double
Double
Double
Hex
EuroPak-15a Receiver User Manual Rev 5
Data Logs
Message ID: 630
Binary
Binary
Bytes
Offset
H
0
4
H
4
H+4
4
H+8
4
H+12
4
H+16
8
H+20
8
H+28
8
H+36
8
H+44
8
H+52
8
H+60
8
H+68
8
H+76
8
H+84
H+ 4
4
(#RF*88)