Antispoofing Flag Values - Novatel EuroPak-15a User Manual

Table of Contents

Advertisement

Chapter 5
Syntax:
AGCMODE
FREQUENCY
Field
Field
Name
1
header
2
frequency
3
mode
4
pulsewidth
5
loadvalue
Example:
AGCMODE L1 MANUAL 40 50
46
MODE
[ PULSEWIDTH
Valid Values
ASCII
This field contains the Abbreviated ASCII command name. See Section 4.1
on Page 31.
See Table 15 on Page 45.
See Table 16 on Page 45.
35 to 262144
35 to 262144
Table 17: Antispoofing Flag Values
ASCII
FALSE
TRUE
LOADVALUE ]
Description
Binary
Specifies which signal
type to apply the
command to.
Specifies whether to
use the default or
custom values for the
pulse width and load
value.
Pulse width. A value is
only required when the
mode field is set to
MANUAL.
Modulus load value. A
value is only required
when the mode field is
set to MANUAL.
Description
Antispoofing is disabled.
Antispoofing is enabled.
EuroPak-15a Receiver User Manual Rev 5
Commands
Message ID: 229
Binary
Binary
Format
Bytes
Offset
H
0
Enum
4
H
Enum
4
H+4
Float
4
H+8
Float
4
H+12

Advertisement