5.3.10 Log Request Logs From Receiver - Novatel EuroPak-15a User Manual

Table of Contents

Advertisement

Commands

5.3.10 LOG Request Logs from Receiver

Many different types of data can be logged using several different methods of triggering the log events. See
Chapter 6, Data Logs starting on Page 70 for further information and a complete list of data log structures.
The hold parameter, which is only valid when the ONTIME trigger is being used, will prevent a log from being
removed when the UNLOGALL command is issued. To remove a log which was invoked using the hold
parameter requires the specific use of the UNLOG command.
The period and offset parameters are only valid when the ONTIME trigger is being used as well. For example,
to log data at 1 second after every minute you would set the period to 60 and the offset to 1.
Maximum flexibility for logging data is provided to you by these logs. You are cautioned, however, to
recognize that each log requested requires additional CPU time and memory buffer space. Too many logs
may result in lost data and degraded CPU performance. Receiver overload can be monitored using the
Buffer Over-run bits of the Receiver Status word in any log header.
Syntax:
LOG [ PORT ] MESSAGE
Field
Field
Name
1
header
2
port
3
message
message
4
type
Reserved field required for Binary format only. Set to 0 when entering the
5
command in Binary.
6
trigger
7
period
offset
8
9
hold
EuroPak-15a Receiver User Manual Rev 5
[ TRIGGER ] [ PERIOD
Valid Values
ASCII
This field contains the Abbreviated ASCII command name. See Section 4.1 on
Page 31.
See Table 10 on Page 39.
Any valid message
name, with a suffix to
Any valid
specify the output format
message ID
as explained in Section
4.2.3 on Page 35.
This field is only present in Binary format.
See Section 10 on Page 39.
See Table 27 on Page 60.
Any positive double value.
Any positive double value smaller than
the value specified in the period field.
See Table 28 on Page 60.
[ OFFSET ] [ HOLD ] ]
Description
Binary
Serial port at which to
output the log data.
Log to output
Message type of log.
Trigger, or condition,
to generate log on.
Log period for
ONTIME trigger in
seconds
Offset for ONTIME
trigger in seconds.
Flag for whether or
not the log is removed
by the UNLOGALL
command. Valid for
ONTIME trigger only.
Chapter 5
Message ID: 1
Binary
Binary
Format
Bytes
Offset
H
0
Enum
4
H
H+4
UShort
2
Char
1
H+6
Char
1
H+7
Enum
4
H+8
Double
8
H+12
Double
8
H+20
Enum
4
H+28
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Europak-15at

Table of Contents